Technical Specification of HU 1.2KVA/2.4KVA/ 3.6KVA/ 5KVA/ 6KVA/ 8KVA | ||||||||
---|---|---|---|---|---|---|---|---|
Model | HU-103 | HU-203 | HU-303 | HU-503 | HU-603 | HU-803 | ||
Capacity | VA / Watt | 1.2KVA/800W | 2.4KVA/1600W | 3.6KVA/2400W | 5KVA/4000W | 6KVA/6000W | 8KVA/8000W | |
Input | Nominal Voltage | 110/115/120Vac or 220/230/240Vac | 220/230/240Vac | |||||
Voltage Range | Acceptable Voltage Range | 60~135Vac or 120~270Vac | 120~270Vac | |||||
Frequency | 45Hz ~ 70Hz Auto-sensing | |||||||
Low Voltage Transfer | 60Vac+/-2% ; 120Vac+/-2% | 120Vac+/-2% | ||||||
Low Voltage Return | 65Vac+/-2% ; 130Vac+/-2% | 130Vac+/-2% | ||||||
High Voltage Transfer | 135Vac+/-2% ; 270Vac+/-2% | 270Vac+/-2% | ||||||
High Voltage Return | 130Vac+/-2% ; 260Vac+/-2% | 260Vac+/-2% | ||||||
Output | Voltage | 110/115/120Vac or 220/230/240Vac re-settable via LCD panel | ||||||
Voltage Regulation(Bat. Mode) | <3% RMS for entire battery voltage range | |||||||
Frequency Regulation | Line Mode | Synchronized to AC Main | ||||||
Battery Mode | 50Hz or 60Hz ±0.1Hz | |||||||
Power Factor | 0.67 | 0.8 | 1.0 | |||||
Wave Form | Pure Sine wave | |||||||
Effeciency | >75% | >80% | ||||||
Overload Protection | Line Mode | >110%,then Buzzer Alarm and Amber LED Blink Continuously. | ||||||
Battery Mode | 110%~150% for 30 sec; >150% for 200ms, then UPS Shuts Down | |||||||
Short Circuit Protection | Line Mode | Circuit Breaker | ||||||
Battery Mode | Electronic Circuit | |||||||
DC Start | Cold Start | Yes | ||||||
Transfer Time | Typical | < 8 ms. | ||||||
Battery | Battery Voltage | 12Vdc | 24Vdc | 48Vdc | ||||
Backup Time | Base on the batteries connected | |||||||
Recharging Current | >40A | >50A | >60A | |||||
Control Panel | LCD Display | UPS status, I/P&O/P Voltage Frequency, Load Level, Battery Voltage & Level, Temperature, Model | ||||||
LED Display | Normal (Green), Warning (Amber), Fault (Red) | |||||||
Audible Alarm | Battery Mode | Beeping every 4 seconds | ||||||
Low Battery | Beeping every second | |||||||
UPS Fault | Beeping Continuously | |||||||
Overload | Beeping twice per second | |||||||
Parameter Re-settable | Voltage,Frequency,5 steps Charge current | |||||||
Environment | Operation Temperature | 0-40 degree C; 32-104 degree F | ||||||
Relative Humidity | 0-95% non-condensing | |||||||
Audible Noise | Less than 55dBA (at 1M) | |||||||
Physical | Wall Mounted Type(W*H*D)mm | 298*400*150 | 298*450*190 | 298*450*190 | 415*600*260 | 415*600*260 | 415*600*260 | |
Wall Mounted Type Net Weight (Kgs) | 14.8 | 23.0 | 24.2 | 49.2 | 51.4 | 53.6 | ||
Safety Conformance | Safety Standard | EN62040-1-1 | ||||||
EMC | EN62040-2 | |||||||
Marks | CE, cUL, UL |