Long-Run 6KVA~60KVA

Availability: In stock

Model number: Long-Run-6KVA-60KVA

Inquiry
Quantity

ONLINE UPS " Tower Long-Run Ver. " UHT-L 6KVA ~ 20KVA.

Feature :
  • Multiple Microprocessor design base
  • Detachable control panel with LCD
  • Unity input power factor and wide input range
  • Robust design with output transformer
  • True sine-wave double conversion on-line UPS
  • DC start and automatic self-diagnostic function
  • RS232 communication port and built-in SNMP slot
  • High efficiency design to save electricity
  • Low heat dissipation in long term operation
  • Designed to operate under harsh environment
  • Enhanced protections against lighting surges, disturbances etc..
Specifications:
Technical Specifications Of "S" & "D" Series UPS
 Single in and single outThree ins and single out
MODES1KS2KS3KS6KS10KS15KS20KD6KD10KD15KD20KD30KD40KD50KD60K
CAPACITY (KW)1KVA/0.82KVA/1.63KVA/2.46KVA/4.810KVA/815KVA/1220KVA/166KVA/4.810KVA/815KVA/1220KVA/1630KVA/2440KVA/3250KVA/4060KVA/48
VOLTAGESingle phase with two lines + ground wire , 220V ± 25%Three phase with four  lines + ground   wire , 380V ± 25%
BATTERY VOLTAGE96V192V192V / 384V384V
NOISE≤ 52 dB ( distance 1m )≤ 60 dB ( distance 1m )≤ 60 dB ( distance 1m )≤ 65 dB ( distance 1m )
SIZW ( W×D×H mm )260 × 545 × 590343 × 630 × 725390 × 620 × 1100900 × 660 × 1470
WEIGHT ( Kg )                 (excluding the battery)30404560105130160130165190210400450530620
INPUTFREQUENCY50 Hz / 60 Hz ± 10%
POWER ACTOR≥ 83%
OUTPUTVOLTAGE220V ± 0.5%
VOLTAGE REGULATIONStable voltage  ± 1% , dynamic voltage  ± 2% , ( 0 - 100% load fluctuation 20 ms )
FREQUENCY STABLENESS50 Hz / 60 Hz ± 0.5%
FREQUENCY TORSION RATELess than 1 Hz / second
INSTANT LOAD STATUS± 0.4% ( 100% instant load fluctuation )
HARMONIC DISTORTIONFor linear load , less than 3% ( full load ) , total rectifying harmonics  is less than 5%
OVERLOAD CAPACITANCE110%
WAVE FORMSine wave
EFFICIENCYINPUT AC TO OUTPUT ACAbove 95%
TRANSFER TIMEMAINS POWER SUPPLY FAILS OR RESTORES0 second
TURNS FROM UPS TO BYPASSless than 4 ms
BATTERYTYPELead - acid sealed , maintenance  - free
CHARGING TIMEAfter it is fully charged  it can be filled  to 90% of the total Capacity after it is charged  for 8 hours
WARNING SOUNDBATTERY DISCHARGEIf the main power fails , it buzzes once every 4 seconds
If the battery is low , it buzzes once every 1 second
 Single in and single outThree ins and single out
MODES1KS2KS3KS6KS10KS15KS20KD6KD10KD15KD20KD30KD40KD50KD60K
WARNING SOUNDBATTERY      DISCHARGEIf the battery stops discharging , it buzzes continuously
IN FAULT STATUSContinuously buzzes
INTERNAL PROTECTIN G
DEVICE LCD PANEL
BATTERYAutomatically shuts down the machine when the battery power is low, it has no fuse switch protection.
OVERLOADAfter the overload  (100~110%) lasts for 3 seconds ,it automatically jumps to BYPASS.
It can automatically restore normal  state.
TEMPERATURE IS TOO HIGHIf the internal  temperature of the UPS>85°C, it will Automatically jump  to BYPASS.
OUTPUT SHORT CIRCUITLimits Current, automatically shuts down the machine, without Fuse switch protection.
UPS IS ABNORMALAutomatically jumps  to BYPASS mode  and starts direct mains power supply.
NOISE FILTER10~10KHz at 40 db; 100KHz~100MHz at 70 db
LCD DISPLAYIndicating input and output voltage,  frequency;  battery voltage  and output power (%);Temperature
BATTERY BVLOne LED, it glows when the battery voltage  is low.
OUTSIDE ENVIRONM ENTTEMPERATURE- 10 ~ 50℃
RELATIVE HUMIDITY0%~93% (No condensation)
OPERATION CONDITIONLower than 3000 meters above sea level (altitude)